Function/Program 

0-59 

Reserved 

60-79 

colour  Motor  and gobo  Motor reset 

80-99 

all  Motor reset 

100-119 

Run  with Internal program 1   built-in 

120-139 

Run  with Internal program 2   built-in 

140-159 

Run  with Internal program 3   built-in 

160-179 

Run  with Internal program 4   built-in 

180-199 

Run  with Internal program 5   built-in 

200-219 

Run  with Internal program 6   built-in 

220-239 

Run  with Internal program 7   built-in 

240-255 

Run  with Internal program 8   built-in 

 

 

CLEANING AND MAINTENANCE 

The operator has to make sure that safety-relating and machine-technical installations are inspected by an expert after 
every four years in the course of an acceptance test. 
 
The operator has to make sure that safety-relating and machine-technical installations are inspected by a skilled 
person once a year. 
 
The following points have to be considered during the inspection: 
1)  All  screws  used  for  installing  the  devices  or  parts  of  the  device  have  to  be  tightly  connected  and  must  not  be 

corroded. 

2)  There must not be any deformations on housings, fixations and installation spots (ceiling, suspension, trussing). 
3)  The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or sediments. 

Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any 
safety problems have to be removed. 

 

 

DANGER TO LIFE! 

Disconnect from mains before starting maintenance operation! 

 
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or solvents! 
 
The interior of the device should be cleaned at least annually using a vacuum-cleaner or an air-jet. 
 
There are no serviceable parts inside the device except for the lamp and the fuse. Maintenance and service 
operations are only to be carried out by authorized dealers. 
 
 

TECHNICAL SPECIFICATIONS 

Power supply: 230 V/50 Hz 
Power consumption: 90W 
Led: 60W white LED 
DMX-control-channels: 10CH 
DMX-512-connection: 3-pin XLR 
Sound-control: via built-in microphone 
Number of colours: 8 di white 
Number of gobos: 7 gobos + open 
PAN-movement: within 180° 
TILT-movement: within 90° 
Fuse: F2A, 250V. 
Packing Size (LxWxH): 465 x 200 x 150 mm 
Net Weight: 5.0 kg  

www.musicstore.com 

Summary of Contents for LIG0009235-000

Page 1: ...anual Page 5 10 LIG0009235 000 Lieber Kunde vielen Dank das Sie sich für ein Produkt von LightmaXX entschieden haben In der folgenden Anleitung erhalten Sie wichtige Informationen über dieses Produkt sowie deren Eigenschaften und Funktionen ...

Page 2: ...t Adresse SOUND MAST SO M Sound Aktiv als Mastergerät ALON SO A Sound Aktiv eigenständig AUTO MAST AU M Automatikbetrieb als Mastergerät ALON AU A Automatikbetrieb eigenständig RPAN ON OFF PAN Bewegung tauschen umkehren RTIL ON OFF TILT Bewegung tauschen umkehren RDIS ON OFF Display anzeige drehen MIC M XX Empfindlichkeit des internen Mikrofons FITI 0000 9999 Stunden Betriebsstundenanzeige REST RE...

Page 3: ...20 29 gobo 2 30 39 gobo 3 40 49 gobo 4 50 59 gobo 5 60 69 gobo 6 70 79 gobo 7 80 99 gobo 1 shake 100 119 gobo 2 shake 120 139 gobo 3 shake 140 159 gobo 4 shake 160 179 gobo 5 shake 180 199 gobo 6 shake 200 219 gobo 7 shake 220 255 Goborad Rotation 5 Gobo Rotation 0 127 Keine Rotation 128 191 Gobo Rotation vorwärts 192 255 Gobo Rotation rückwärts 6 Focus 0 255 Motorischer Fokus 7 Shutter 0 9 geschl...

Page 4: ... Reset 80 99 Komplett Reset 100 119 Start internes Programm 1 120 139 Start internes Programm 2 140 159 Start internes Programm 3 160 179 Start internes Programm 4 180 199 Start internes Programm 5 200 219 Start internes Programm 6 220 239 Start internes Programm 7 240 255 Start internes Programm 8 www musicstore de ...

Page 5: ... condensation water might damage your device Leave the device switched off until it has reached room temperature Please make sure that there are no obvious transport damages Should you notice any damages on the A C connection cable or on the casing do not take the device into operation and immediately consult your local dealer This device falls under protection class I The power plug must only be ...

Page 6: ...ily mean that the device is defective Caution During the operation the housing becomes very hot Do not switch the device on and off in short intervals as this would reduce the lamp s life HEALTH HAZARD Never look directly into the light source as sensitive persons may suffer an epileptic shock especially meant for epileptics Keep away children and amateurs Never leave this device running unattende...

Page 7: ...hermore any other operation may lead to dangers like short circuit burns electric shock lamp explosion crash etc Occupation of the XLR connection DMX output XLR mounting socket DMX input XLR mounting plug 1 Ground 2 Signal 3 Signal 1 Ground 2 Signal 3 Signal If you are using controllers with this occupation you can connect the DMX output of the controller directly with the DMX input of the first f...

Page 8: ...the motors are trimmed and the device is ready for use within approximately 20 seconds Turn the objective lens for adjusting the focus in order to obtain a sharp projection LED display instructions A001 AXXX AXXX DMX Address SOUND MAST SO M Sound active as MASTER fixture ALON SO A Sound active independently AUTO MAST AU M Auto run as MASTER fixture ALON AU A Auto run independently RPAN ON OFF Reve...

Page 9: ... 119 gobo 2 shake from slow to fast 120 139 gobo 3 shake from slow to fast 140 159 gobo 4 shake from slow to fast 160 179 gobo 5 shake from slow to fast 180 199 gobo 6 shake from slow to fast 200 219 gobo 7 shake from slow to fast 220 255 Gobo wheel rotation with increasing speed 5 Bobo Rotation 0 127 No rotation 128 191 forwards gobo rotation with increasing speed 192 255 Backwards gobo rotation ...

Page 10: ...ot be any deformations on housings fixations and installation spots ceiling suspension trussing 3 The electric power supply cables must not show any damages material fatigue e g porous cables or sediments Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed DANGER TO LIFE Disconnect from mains before ...

Reviews: