Set-Up:

Before attempting any operation, be sure you set up your system prop-

erly. Also, be sure all DMX setting are properly adjusted. Refer to the 

last pages of this manual for proper fixture positioning and DMX chan-

nel settings that correspond with the fixtures you will be using. If you will 

be customizing the Auto-Mate/DMX™ (creating your own programs), 

always leave the first 4 DMX Channels (000 – 003) free, the Auto-Mate/

DMX™ needs these channels for internal instructions. All DMX fixtures 

should always start on DMX a address 004. 

Function Levels:

The Auto-Mate/DMX™ has two different function levels. Function level 

one is the default setting and will be indicated when the red LED above 

the function key is not glowing. A red LED located above the function 

key indicates function two. Function level one allows you access to, and 

changes the four available chase programs patterns. Function level two 

allows you to change the different operating modes.

  

Operation (Plug and Play):

When  switching  the  Auto-Mate/DMX™  on,  it  will  immediately  enter 

blackout mode. Selecting any of the four program buttons under func-

tion level one will immediately begin program playback.

Function level 1: (Red LED Off): 

Selecting any of the four PROG keys while the Function LED is not 

glowing will initiate any program stored in the corresponding memory 

bank. A green LED above the selected program will indicate which pro-

gram is selected. When you select a new program the corresponding 

green LED will begin to glow. 

Function level 2: (Red LED On):

Tapping the Fast or Slow Key more than once will stop the program. 

The fixtures will not blackout, but will freeze on a scene. Tapping Fast 

or Slow again will continue the program from that point.  This function 

will be indicated when either the Fast or Slow key LED indicator is flash-

ing. To exit this function, deselect the fast or slow key or begin a new 

program.

Blackout:

The function will stop the running program and will close the 

shutters of all fixtures. 

  Auto-Mate/DMX™  

 

 

 

     Operation

  Auto-Mate/DMX™  

 

       Installing Programs

©

LSC Supply

®

  -  www.lightstreamcontrols.com  - Auto-Mate/DMX™ Instruction Manual Page 10

©

LSC Supply

®

  -  www.lightstreamcontrols.com  - Auto-Mate/DMX™ Instruction Manual Page 9

Installing your own Programs:

A second way you can use the Auto-Mate/DMX™ is to store your own 

programs from an external DMX Controller such as the popular LSC

®

 

Show Designer.™ These programs can then be used to automatically 

run  your  unit  as  the  original  built  in  program  would.  This  operation 

allows you to customize your programs to meet your individual needs.

Procedure:

First,  program  your  desired  scenes  in  any  DMX  Controller.  You  can 

create a total of eight programs, four programs can be stored on bank 

one (

Fast

) and four can be stored on bank two (

Slow

). The programs 

can  not  consist  of  more  than  256  DMX  channels  and  60  scenes  or 

steps. 

When  you  have  created  programs,  upload  them  Scene  by  Scene  to 

the Auto-Mate/DMX.™ When programming the Auto-Mate/DMX,™ the 

DMX Information for the time interval between scenes, the Strobe func-

tion, and the Blackout function must be programmed separately. When 

uploading your scenes to the Auto-Mate/DMX™ use DMX Channel 001 

to set the time interval between your scenes, use DMX Channel 002 to 

set the strobe information in your scenes, use DMX Channel 003 to set 

the blackout information. 

Summary of Contents for Auto-Mate/DMX

Page 1: ...tion 3 SafetyPrecautions 4 ConnectionandDMXSetup 5 Controls and Function 7 Operation PlugandPlay 9 InstallingPrograms 10 ActivatetheRecord Mode 11 DataExchange 12 Set Up Procedures MightyScan 13 Max 1...

Page 2: ...uto Mate DMX has been thoroughly tested and has been shipped in perfect operating condition Carefully check the shipping carton for damage that may have occurred during shipping If the carton appears...

Page 3: ...variations in line voltage from venue to venue be sure to plug your power supply into a wall outlet with matching power before attempting to operate Data Cable DMX Cable Requirements Connect the Auto...

Page 4: ...s When the function level two is engaged this button will activate sound active mode When the function level one is engaged selecting this button will active the program stored in this bank 7 Strobe P...

Page 5: ...once will stop the program The fixtures will not blackout but will freeze on a scene Tapping Fast or Slow again will continue the program from that point This function will be indicated when either th...

Page 6: ...ider value 10 is equal to one second Slider value 20 is equal to two second Slider value 30 is equal to three second etc 4 Save scene into memory by pressing the Audio Key when the scene has been stor...

Page 7: ...e the set tings and positioning for fixtures 5 6 7 and 8 When using only four units in your system ignore the set tings and positioning for fixtures 5 6 7 and 8 DMX 040 DMX 004 DMX 016 DMX 028 DMX 010...

Page 8: ...o Mate DMX POWER FUSE OUTPUT INPUT X Calibur 4 POWER FUSE OUTPUT INPUT LSC Supply www lightstreamcontrols com Auto Mate DMX Instruction Manual Page 16 LSC Supply www lightstreamcontrols com Auto Mate...

Page 9: ...ow 1 1 10 9 8 7 6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 Rainbow 4 Rainbow 3 Rainbow 2 ON ON ON ON Auto Mate DMX Rainbow 250 Set Up LSC Supply www lightstreamcontrols com Auto Mate DMX Inst...

Page 10: ...4 3 2 1 10 9 8 7 6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 DJ Scan 4 DJ Scan 3 DJ Scan 2 Auto Mate DMX DJ Scan Set Up Auto Mate DMX DJ Roller Set Up LSC Supply www lightstreamcontrols com Auto Mate DMX Instructi...

Page 11: ...nts upon its prod ucts without any obligation to include these changes in any products theretofore manufac tured F No warranty whether expressed or implied is given or made with respect to any acces s...

Page 12: ...htstreamcontrols com MODEL AUTO MATE DMX SPECIFICATIONS VOLTAGE 9v 12v AC WEIGHT 2 5 LBS 1 5 KGS FUSE 2 AMP GMA INTERNAL WORKING POSITION ANY SAFE POSITION PROGRAMS 8 TOTAL 2 BANKS 60 SCENES PER A PRO...

Reviews: