Light Controller
Three-color light controller indicates
acceptable levels. Red flashing light
indicates improper hand placement,
green flashing light indicates proper
ventilation volume, and yellow flash-
ing light indicates proper compression
depth. Child CPR can be practiced
by changing the compression springs
and flipping the switch on the light
controller.
LF03401U
Adult/Child
Switch on all
Monitors
LF03403U
External Electronic Monitors
Simple and accurate feedback!
Select one of the four modes (com-
pression rate, compression depth,
ventilation duration, ventilation vol-
ume) by pushing indicator switch.
Red light indicates improper hand
placement, yellow light signals
proper compression depth of 1.5-2.0
inches adult/1.0-1.5 inches child.
Green light signals proper ventila-
tion volume at 0.80 liters adult/0.50
liters child. The performance of each
skill is displayed separately while
averages are stored in the memory.
Designed to automatically switch
between the compression and ven-
tilation modes depending on which
one is being applied.
Electronic Monitoring,
Memory, and Printer Unit
For testing, simply push test start but-
ton and begin CPR sequence.
Compression and ventilation wave-
forms are plotted in a time sequence.
When stop button is pushed, averag-
es of the four skills are shown on the
digital display while the printer tabu-
lates the result on paper.
Electronic Monitoring and
Memory Unit
Provides same visual feedback as
LF03401(X)U, but without printer
component.
PROCEDURE:
LIGHT CONTROLLER/SETUP
Remove the cover using a medium-
sized phillips head screwdriver.
Batteries are included (use “C” cell
alkaline batteries).
Operation:
1. Connect the controller to the man-
ikin with the interface jack.
2. Select adult or child mode at
switch.
Hand Placement (Red Light):
The placement light will turn on
every time the chest is compressed
1.00 inch and the proper hand place-
ment has not been accomplished.
Procedure D