LIFE FITNESS specifies Hilti™ static and dynamic anchors. According to the anchor manufacturer, the recommended
design pullout force (in tension) for the specified anchors, when properly installed in cracked concrete, is provided in
the side table. This table should be used for reference only; for additional and up-to-date information on the anchor
capabilities or the design pullout force in other substrates, please consult Hilti directly at https://www.us.hilti.com.
SELECTED ANCHOR
DESIGN RESISTANCE IN TENSION
KH-EZ ¼” x 4”
830 lb
HUS-H 6mm x 120mm
3.3 kN
KH-EZ 3/8” x 4”
1535 lb
KH-EZ 3/8” x 5”
1535 lb
HUS-H 8mm x 120mm
3.3 kN
HUS-H 8mm x 150mm
3.3 kN
HSL-3/8 4”
2000 lb
HST M12 x 115/20
8 kN
HST M12 x 195/200
8 kN
KB-TZ 3/8” x 3-3/4”
1615 lb
* Design strength extracted from the Hilti Anchor Fastening Technology Manual issued September 2014.
Adhere to manufacturer’s equipment warnings and guidelines. Follow manufacturer’s instructions for proper usage.
Floor scanner/rebar detector (optional)
Safety glasses
1” L-shape SDS rotary hammer
Extension cord
Dead blow hammer
Impact wrench
1/2” x 12” (12mm x 305mm) carbide drill bit (for 1/2” (12mm) anchors)
Vacuum (for debris)
Pullout Force
Tools Required
Summary of Contents for MJ-CORE
Page 2: ......
Page 17: ...14 Assisted Dip Chin MJADC STA ITEM NO DESCRIPTION QTY 1 Serial Number 1 2 Placard 1...
Page 25: ...22 Handle Accessory Rack MJHAR STA ITEM NO DESCRIPTION QTY 1 Serial Number 1...
Page 29: ...26 Low Row MJRW STA ITEM NO DESCRIPTION QTY 1 Serial Number 1 2 Placard 1...
Page 31: ...28 Tricep Pushdown MJTP STA ITEM NO DESCRIPTION QTY 1 Serial Number 1 2 Placard 1...
Page 65: ...62 MJADC MJAP MJAP41 MJACO and MJAXO MJDPH MJACO 11 Cable Routing...
Page 66: ...63 MJDPL MJLPD MJHL MJFCO MJFXO MJLP...
Page 67: ...64 MJTP MJRW MJRWD...