67
Cable Terminations
Check Cable Terminations
1.
Correct Depth: cable exceeds minimum depth
Incorrect Depth: cable not deep enough
Cable terminations must have a minimum thread engagement of at least 1/2” (12.7mm). Check each cable end to
ensure it is properly connected.
Head Plate Cable Terminations
Heim Joint Terminal
Carriage Terminal
Heim Joint and Carriage Terminations:
• Measure cable’s threaded plug to determine the minimum depth requirement has been met.
25-30 FT-LBS.
(27-34 Nm)
Once the minimum thread engagement has been verified, tighten jam nut.
Attempt to slide a 7mm Allen wrench into the headplate as shown below.
• Correct Depth - Wrench cannot pass through bayonet (cable assembly at least at minimum depth).
• Incorrect Depth - Wrench can pass through bayonet (cable assembly not deep enough - recalibrate).