background image

5

Hoods (2)
c/w Bug Screen

Motors (2)

Supply Duct

24"x16"

Drain Pans (2) 

Heat Exchange Core

Exhaust Duct

24"x16"

4" Filters

Supply Hoods

Exhaust 
Hoods

Roof Curb

Heat 
Exchanger
Service 
Panel*

Filter
Service 
Panel*

Electrical
Service
Panel*

47"

18"

18"

27"

89.9"

SIDE VIEW

BOTTOM VIEW

*NOTE: Removable service access panels on both sides of 2500EFD cabinet.

*NOTE: Roof curb is one inch smaller than outside dimensions of cabinet.

38.4"

28"

19.2"

44.95"

44.95"

Bottom duct
connections

16" X 24"

Centre

Point

Fresh Air

Supply

Hood

Hood

Stale Air

Return

89.9"

8"

8"

21.8"

25"

8"

8"

12"

12"

12"

12"

DATE: ____________________________________________PROJECT: ________________________________________

MECHANICAL CONTRACTOR: __________________________________________________________________________

Model 2500EFD

(ROOFTOP)

TI-91E

1203

All units conform to CSA and UL standards.   

SPECIFICATIONS

AIR FLOW
2100 cfm (985 L/s) at 1.0"wg ESP

PERFORMANCE
70% effective at 2500 cfm (1172 L/s)

CORE
Modular aluminum sensible heat recovery core.  
Plate-to-plate type.  Slides out of either side of cabinet
for service.

MOTORS
Two single shaft PSC, 3-speed, 208/230V,5.1 amps, 1 ph,
1 hp

BLOWERS
Two direct-drive centrifugal blowers, one per air stream.

FILTERS
Two 18" X 24" 4-inch pleated filters in each air stream.

DUCT CONNECTIONS
Four 24" X 16" (610mm X 406mm) to and from the building
under cabinet. Four 28" X 18" (711mm X 457mm) hoods
included on side of cabinet with screens.

CABINET
20 gauge powder coated galvanized steel (G60) for
superior corrosion resistance. 16 gauge galvanized
frame, insulated with 1.5" fibreglass insulation to pre-
vent condensation.

DRAIN
Two stainless steel drain pans with 1/2" NPT drain
spouts.

MOUNTING
Rooftop mounted on optional roof curb (Part No. 53-
2500) 

CONTROLS

24V terminal strip inside electrical box, to connect
optional remote controls (not included), obtain on/off
and high/low functions.

DEFROST
Factory set defrost time (user adjustable).
Supply motor is shut off while exhaust air defrosts core.

WARRANTY
15 year warranty on heat exchanger, and 2 years on
parts.

WEIGHT
700 lbs.

SHIPPING WEIGHT
1100 lbs.

OPTIONAL CURB
WEIGHT 50 lbs.

Summary of Contents for 2500EFD

Page 1: ...nstallation the compatibility of the two pieces of equipment must be confirmed by measuring the airflow s of the Heat Recovery Ventilator HRV Energy Recovery Ventilator ERV by using the balancing proc...

Page 2: ...will help in cooling the incoming fresh air with the stale air that is being exhausted Table of Contents Introduction 2 Select Correct HRV 3 Specifications Model 2500IFD 4 Specifications Model 2500EF...

Page 3: ...required 45 x 20 900 cfm 450 L s Bank Customers 25 Staff 9 Total 34 ASHRAE requirement 20 cfm 10 L s per person Ventilation required 34 x 20 680 cfm 320 L s Bar or Tavern Seats 50 Employees 7 Total 5...

Page 4: ...n each air stream DUCT CONNECTIONS Four 24 X 16 610mm X 406mm CABINET 20 gauge powder coated galvanized steel G60 for superior corrosion resistance 16 gauge galvanized frame insulated with1 5 fibregla...

Page 5: ...ar aluminum sensible heat recovery core Plate to plate type Slides out of either side of cabinet for service MOTORS Two single shaft PSC 3 speed 208 230V 5 1 amps 1 ph 1 hp BLOWERS Two direct drive ce...

Page 6: ...ANK TIMER Mechanical timer to activate high speed 99 116 DEHUMIDISTAT VENTILATION CONTROL DVC Turns unit on off via slider switch and high low via built in dehumidistat 99 130 DEHUMIDISTAT Activates h...

Page 7: ...used to control the unit see pg 9 Installation Tips 1 Whichever method is chosen to operate the 2500 keep in mind that Air to Air exchangers in general are not booster fans and are normally sized to v...

Page 8: ...humidity level exceeds selected setting PART NO 99 130 CRANK TIMER Provides high speed ventilation as required Crank Timer 60 minute PART NO 99 101 ON OFF HIGH LOW COMMON I I I I I I I I I I I I I I I...

Page 9: ...e where the surrounding air temperature does not fall below freezing point The exhaust air temperature must be above 60 F 16 C for proper defrost operation If the air temperature is too low the defros...

Page 10: ...n and slope of drain lines Vibration isolators May be anchored to floor leaving space for drain connections 2500IFD Saddle mount not provided Hang unit with threaded rods and U channel members 2 X 4 u...

Page 11: ...RAME To ensure proper mating with unit it is critical that mounting frame be squared to the roof as follows 1 With frame situated level in desired location on roof trusses tack weld one corner of fram...

Page 12: ...elsewhere and provided by the contractor The 2500EFD has built in screens to prevent foreign objects from entering into the ductwork through the out side hoods NOTE It is extremely important to desig...

Page 13: ...grilles should be located high on the wall If contaminants are heavier than air a lower placement of the grilles will be required Information on a contaminants specific gravity and toxicity should be...

Page 14: ...wnstream of any elbows or bends and one foot upstream of any elbows or bends These are recommended distances but the actual installation may limit the amount of straight duct The Pitot tube should be...

Page 15: ...d the HRV Electrical Connections System is 208 230V 1 phase 60 Hz This unit meets all local codes and requirements It is STRONGLY recommended that an electrical disconnect be installed prior to the HR...

Page 16: ...UNIT Check design static pressure of air handler to ensure it is compatible with HRV B A ROOFTOP HEAT COOL UNIT SUPPLY DUCTWORK CEILING RETURN AIR PLENUM ROOF DECK STALE AIR EXHAUST HRV FRESH AIR SUP...

Page 17: ...LOW TIMER ON OFF ON OFF 24V F1 XFRM1 240V 240 VAC 15 AMPS COMMON 24 VAC 24 VAC TI 109 07 97 5 AMP COMMON HIGH LOW HIGH LOW SNAP DISK C3 HIGH BLACK HIGH YELLOW COM BLUE MID RED LOW EXHAUST MOTOR EXHAU...

Page 18: ...5A 5A ON OFF HIGH LOW SNAP DISK TM1 1 R2 1 R1 1 R3 1 R4 1 R3 1 R3 1 R3 1 Blk High Red Low Blk High Red Low Yel Com Yel Com Yel Com Yel Com XFMRI SM SM EM EM Exhaust Motor SM Supply Motor EM R2 R3 R1 R...

Page 19: ...d London Ontario N5W 4C8 519 457 1904 or fax 519 457 1676 to find the name of your nearest dealer in order to repair the product The labour required to install any replacement part s shall be dealt wi...

Page 20: ......

Reviews: