1. Turn off power to the ionizer by pressing the circle side of the power
switch located at the bottom of the ionizer.
2. Remove the
#2 filter
cover located on the right side when looking
at the back of the ionizer
.
3. Remove the #2 filter by twisting the filter and then lifting it out of the
ionizer.
4. Remove the clear plastic packaging and dust cover from the bottom
of the scaling filter.
5. Before installing the filter, lube up the large outer O-ring with either
olive oil or vaseline. Line up the 2 tabs on the filter to the filter base
in the ionizer.
6. Once you have aligned the tabs on the filter with the ionizer,
press down and twist the filter until it stops.
7. Replace the cover and turn the power switch back on.
8. Apply water pressure, press the
“ON/OFF”
button and run for 15
seconds. Press the
“ON/OFF”
button to stop extraction. For counter
top applications, remove the acidic tube from the sink and fasten it
to the ionizer ensuring that the cleaning solution will not leak out of
the ionizer.
Now let the unit sit for a minimum of 6-8 hours. The unit is full of
a citric acid solution that will take many hours to break down the
scale that has built up in your unit. Letting it sit in the unit for over a
6 hour period is okay and will not harm the ionizer.
9. Once the unit has sat for the recommended time, (leaving scaling
filter in place) unfasten the acidic tube from the ionizer and place
it back in the sink (for counter top applications) and then press the
center
“ON/OFF”
button and then immediately select the
“PURIFY”
button. Let the unit extract water for 3-5 minutes. This step will
purge all of the citric solution, along with any scale, out of the
machine.
The cleaning process is now complete. Remove the scaling filter and
throw it way or recycle it and reinstall a #2 filter.
NOTE: If you are putting in any new filters, do so after the cleaning.