www.LifeIonizers.com/Support
29
75
M11/M11 UC NG
www.LifeIonizers.com/Support
Pre-Filter Replacement
1. Shut off water supply at source (cold water
connect or diverter valve). Turn on the ionizer
to relieve water pressure. Shut off ionizer.
2. Disconnect 1/4” tubing from inlet and outlet
from pre-filter. Press and hold the collar in and
then pull on tubing to release. The collar must
be held until tubing is removed.
3. Lay down the pre-filter and use the
pre-filter wrench (sent with your pre-filter
order) to loosen filter from housing. Slide
pre-filter wrench from bottom to top. Twist
pre-filter wrench counter clockwise to loosen.
4. Remove filter from bracket and lids (Do not
remove the bracket from the lid/lids). Discard
old pre-filter. Install new pre-filter (Some are
directional. These will say “this side toward cap”).
5. Lube up large
black O-ring
located in
filter next to the
threads.
6. Install filter with filter onto the cap. Tighten
clockwise using pre-filter wrench
7. Repeat process if needed to your other filters.
8. Connect inlet and outlet tubing.
9. Apply water pressure.
10. Run ionizer on
“PURIFY”
mode for around 3-5 minutes to flush out pre-filter.
* Pre-filters should be replaced every year.
* Pre-filter housings should be replaced every 2 years.
See page 16 for help on Quick
Connect Fittings and Tubing.