34
Troubleshooting
IF THE ENGINE WILL NOT START:
1.
Check to ensure switches are in the “ON” position. (Both unit and engine)
2.
Check engine oil level. Your unit possesses a Low Oil Alarm System that will not allow your
engine to start if the oil is below safe operating levels. This feature is installed to increase
the life of your engine and prevent engine damage. If oil level is low, fill to the full mark on
dipstick. Refer to the Product Specifications for exact oil type and amounts.
3.
Check the fuel level to insure adequate fuel. Add fuel if necessary.
4.
Remove and inspect the spark plug for cleanliness and proper electrode gap. If needed,
clean or replace the spark plug. Refer to Spark Plug Maintenance in the Maintenance
section of the Owner’s Manual for proper procedure.
5.
If your unit will still NOT start after performing the above checks, call our customer hotline
at LIFAN Power USA Toll Free 1-‐‐866-‐‐471-‐‐7464 OPTION 2.
NOTE:
Periodically on the initial start-‐‐up or after the unit has been stored for a long
period of time, the float for the “Low Oil Alarm System” will stick to the bottom of
your oil pan. Locate the two (2) wires to the Low Oil Sensor Diode (refer to figure on
the right) located on the side of the engine block. Unplug these wires and,
only
after ensuring the engine is full of oil,
start the engine and allow to run until warm
(normally 20 minutes, as this will heat the oil and release the float on the Low Oil
Alert System). Then re-‐‐ plug the wires to the terminals on the Low Oil Alarm Sending
Uni
UNIT DOES NOT PROVIDE ELECTRICAL CURRENT:
1.
Plug in a small appliance or tool to test. 1.On 2.Off/Tripped 3.On 4.Off
2.
Check if the AC (or DC) Circuit Breaker is in the “ON” position. If not, place in “ON”
position. If equipped with a GFCI receptacle, re-‐‐set GFCI Breaker by pushing in the reset
button in the middle of the GFCI’s faceplate (this must be done with the engine running).
3.
If your unit still does NOT produce electricity after performing the previous checks, call
LIFAN Power USA at 1-‐‐866-‐‐471-‐‐7464, OPTION 2.
UNIT DOES NOT PROVIDE ELECTRICAL CURRENT
(continued):
4
3
1
2
Summary of Contents for LF4250EPL
Page 1: ......
Page 12: ...11 Voltage Selector Switch RV Model...
Page 13: ...12...
Page 14: ...13...
Page 15: ...14 Controls and Features LF4250EPL CA LF8750IEPL RV CA LF8750IEPL CA LF7250IPL CA...
Page 16: ...15 Controls and Features Of Unit...
Page 20: ...19 Pre Operating Instructions Assembly Diagram...
Page 43: ...42 APPENDIX...
Page 44: ...43 Wiring Diagram LF4250EPL CA...
Page 45: ...44 LF4250EPL CA Exploded View Parts...
Page 46: ...45 Wiring Diagram LF7250iPL CA...
Page 47: ...46 LF7250iEPL CA Exploded View Parts...
Page 48: ...47 Wiring Diagram LF8750iEPL CA...
Page 49: ...48 LF8750iEPL CA Exploded View Parts...
Page 50: ...49 Wiring Diagram LF8750iEPL RV CA...
Page 51: ...50 LF8750iEPL RV CA Exploded View Parts...
Page 53: ......
Page 54: ......