background image

Caution! Operate the device only after having read and 

understood

operating instructions!

2

Mix4-6 Rev.: 1.02

Summary of Contents for Mix4-6

Page 1: ...upply Functional description Mix4 6 Fabrication and Marketing Licht Technik Hagenbach Grill Osterwaldstr 9 10 80805 München Tel 089 360528 0 Fax 089 360528 30 E Mail info Licht Technik com Last updated on 28 09 17 Rev 1 02 Mix 4 6 Rev 1 02 1 ...

Page 2: ...Caution Operate the device only after having read and understood operating instructions 2 Mix4 6 Rev 1 02 ...

Page 3: ...nal faders other devices like color changers or dimmer shutters can be operated A 5pin and a 4pin DMX output can be used at the same time The 4pin output can control the connected devices directly the 5pin can be used to provide a splitbox e g PS104 or PS204 The device can be operated with 100V to 120V AC or 220V to 240V AC The power supply is designed in switching technology to provide high relia...

Page 4: ...ing and safety instructions 5 Cabling 6 Getting started 8 User interface elements 8 Handling Programming 9 Technical data 10 Malfunctions 11 Warranty 12 Further information 12 EC Declaration of Conformity 13 4 Mix4 6 Rev 1 02 ...

Page 5: ...r similar systems Observe mains supply voltage 100 120V AC e g America Japan OR 220 240V AC 50 60Hz When it has to be assumed that a safe operation is no longer possible the equipment must be switched off immediately and be secured against unintended operation This is the case when the equipment shows visible damages the equipment is no longer functional parts of the equipment are loose or slacken...

Page 6: ...20W PS104 respectivly 240W PS204 must be observed The power consumption of every device is indicated on the type plate The total power consumption per Power supply is the sum of the single power consumption of the devices 6 Mix4 6 Rev 1 02 Mains input DMX 5pol XLR Data line Mix4 6 Licht Technik devices DMX 4pol XLR DataPower line Mains switch Connector for further Splitbox 5pol XLR Data line Also ...

Page 7: ...er If more devices should be connected a splitbox must be used The last device in a row should be terminated with a 470 Ohm resistor The maximum lin length must not exceed 80 m DataPower 4pin because of the voltage drop Cabling without Splitbox Connect the Mix4 6 with the devices directly via a 4pin DataPower cable Connect them in a row daisy chain Observe the maximum load of 120W The motoryoke ha...

Page 8: ...rated on page 6 Switch on the device And leave the joystick in the middle position It is calibrated during switching on User interface elements 8 Mix4 6 Rev 1 02 Motoryoke selection Focus Forward Back Flash buttons Joystick for Motoryoke control DMX channels 8 13 Power LED Focus position LED ON OFF Switch Mains input 5pin DMX output 4pol DataPower output ...

Page 9: ...set to 1 It determines that 2 DMX channels for the PAN and TILT speed is used Normally 1 for both speeds See also motoryoke manual Is this value not set to 1 the motoryokes are not controllable from this board Now everything should be programmed correctly With the unit buttons the desired motoryoke system can be selected The corresponding LED lights With the Joystick the motoryoke can be moved The...

Page 10: ...DC min cross section 0 75mm Housing shield OUT 5pin 5pin XLR female gold contacts PIN 1 shield min cross section 0 25mm PIN 2 Data min cross section 0 25mm PIN 3 Data min cross section 0 25mm PIN 4 not connected min cross section 0 25mm PIN 5 not connected min cross section 0 25mm Housing shield Cable 4pin 2 x 1mm2 Power supply Pin 1 and 4 2 x 0 25mm2 twisted 110 Ohm characteristic impedance Pin 2...

Page 11: ... cable to the 4pin output it might be possible to break the DMX line driver This happens when there is a short circuit from 24V to pin 2 or 3 No LED lights after power up Is the mains cable connected Is the device switched on Check the fuse inside the device The motoryoke does not move like desired Are the DMX adresses right programmed Check the printed adresses on the panel and check menu P01 at ...

Page 12: ...e and servicing works related to the product must be carried out by the company Licht Technik Licht Technik shall not assume any liability for losses or damages of any kind being the results of inexpert servicing Further information This document and the information contained therein are subject to copyright and neither the whole nor any part of it may and this is also valid for the described prod...

Page 13: ... innerhalb bestimmter Spannungsgrenzen auf dem Markt 6 Applied and conform to harmonized standards in particular DIN EN 55015 VDE 0875 15 1 2016 04 Grenzwerte und Messverfahren für Funkstörungen von elektrischen Beleuchtungseinrichtungen und ähnlichen Elektrogeräten CISPR 15 2013 IS1 2013 IS2 2013 A1 2015 Deutsche Fassung EN 55015 2013 A1 2015 DIN EN 61547 VDE 0875 15 2 2010 03 Einrichtungen für a...

Reviews: