Malfunctions
Caution! Before opening the housing disconnect the device from electrical mains
Caution!
Change the fuse only in disconnected condition. If the fuse will blow again, the
device has to be repaired by Licht-Technik
Caution!
Replace a defect fuse only with a fuse of the right value
In the inside of the device are no parts which can be repaired by the user!!
The built in power supply is short circuit protected, overload proof and very reliable in
operation. In case of a defect no changable parts can be reached.
When connecting a defect cable to the 4pin output, it might be possible to break the DMX
line driver. This happens when there is a short circuit from 24V to pin 2 or 3.
No LED lights after power up
- Is the mains cable connected?
- Is the device switched on?
- Check the fuse inside the device.
The motoryoke does not move like desired.
- Are the DMX adresses right programmed? Check the printed adresses on the panel
and check menu P01 at the yokes.
- Is the menu P27 set to 1 at the motoryoke?
- Was the joystick touched during power on? If yes, release the joystick at power up again.
No DMX signal on the outputs
- Check the DMX lines for interruption and interchanging of pin 2 and 3.
If the error could not be recovered, the device must be sent to company Licht-Technik.