COMMISSIONING
PRELIMINARY PROCEDURE
Lock the clutch and then gently move the door to the closed position
Power the garage door opener: the courtesy light will turn on, the display shows “0”
and the control unit will
“beep”
once
If no instruction is given for more than 2 minutes the control unit automatically
exits from commissioning mode and any previous adjustment will be deleted
DOOR'S OPENING LIMIT SETTING
DOOR'S CLOSING LIMIT SETTING
Keep pressing “
P
” key
(about 8 seconds)
Till the control unit
beeps once and the
display shows “
1
”
Press “
P
” again,
“
1
” must flash
Keep pressing “
+
” key
Till the door has
come to the complete
open
position
Then press “
P
” key
again to save the setting
Press “
-
” key till the
display shows “
2
”
Press “
P
” , “
2
”
must flash
Keep pressing “
-
” key
Till the door has
come to the complete
closed
position
Then press “
P
” key
to save the setting
The saved information has no effect if this procedure is followed to set
door's closing limit.
The saved information has no effect if this procedure is followed to set
door's opening limit.