background image

E7.

 

E8.

DOOR OPEN ALARM SETTING

The factory setting is “

OFF

”.

AUTOMATIC CLOSING TIME SETTING

This function is normally 

OFF

 from factory settings.

Press “

+

” or “

-

“ to set the automatic closing time according to the following chart: 8 means 240 

seconds (maximum setting), 7 means 210 seconds and so on…

 

Press  “

-

” key till the 

display shows “

7

Press “

P

"

Then press “

+

” to set the 

alarm function 

ON

Or press “

-

“ to set the 

alarm function 

OFF

Then press “

P

” key 

to save the setting

 

30 sec.

 

 

Press “

-

” key till 

the display shows “8”

      

Press “

P

” key till the

display shows “

0

” to 

set the automatic 
closing function 

ON

Press “

+

” till the display 

shows “

1

” to set the 

automatic closing time 
at 30 seconds

 

Then press “

P

” key 

to save the setting

10

60 sec.

180 sec.

90 sec.

210 sec.

120 sec.

240 sec.

150 sec.

 

GB

GB

Summary of Contents for Gear motor 230V for sectional

Page 1: ...stallation et utilisation 2007_01 Motoriduttore 230V per l automazione di porte da garage sezionali o basculanti Automatisme 230V 24V pou porte de garage sectionelles ou basculante d bordante Gear mot...

Page 2: ...away from children Keep watching on the door s movement and do not approach to the door until it s completely open or has come to a complete stop Check regularly the automation operating condition in...

Page 3: ...Straight door bracket 1 Chain 1 Emergency release rope 1 Trolley 1 Gearmotor with incorporated control unit Instructions manual Radio transmitter Bent door arm Mounting bracket Support bracket Front w...

Page 4: ...shown in the picture 3 Join the rail parts together through the provided connectors in a way that the catches are in sight 4 Tighten the nut with a 13 sleeve 5 Adjust distance as shown in the picture...

Page 5: ...oor sight range but far enough from any moving part and at a minimum height of 1 5m Affix in outstanding position or near the permanently mounted controls warning signals indicating the risk of being...

Page 6: ...all Driving screw 6x15 Door Bent door arm Front wall fixing bracket Support bracket Screw 6x80 Screw 8x20 Rail Mounting bracket Rawlplug Rawlplug Door fixing bracket U bracket Inserted pin 8x25 Screw...

Page 7: ...door D GEARMOTOR AND CONTROL UNIT Rail Trolley clutch Emergency rope WHEN POWER RECOVERS Give a start impulse to the garage door opener through the radio transmitter or through a permanently mounted c...

Page 8: ...see page 10 Power failure The door can be open manually by pulling down on the emergency release rope see page 5 Accessory devices A photocell connection is available on the control unit see page 14...

Page 9: ...LIMIT SETTING Keep pressing P key about 8 seconds Till the control unit beeps once and the display shows 1 Press P again 1 must flash Keep pressing key Till the door has come to the complete open posi...

Page 10: ...or stops press P key twice The door automatically closes Then press P key to save the setting Once the full cycle has finished you can press key to select menu 1 and then keep pressing P key till the...

Page 11: ...e photocells beam If the display shows an A then photocells have been connected properly If A does not appear on the display you have to check again the photocells connection Then press P key to save...

Page 12: ...s and so on Press key till the display shows 7 Press P Then press to set the alarm function ON Or press to set the alarm function OFF Then press P key to save the setting 30 sec Press key till the dis...

Page 13: ...e 2000 cycles alert is OFF Press key till the display shows 0 to set the 2000 cycles alert OFF Press key till the display shows 1 to set the 2000 cycles alert ON Press P key to save the settings Exit...

Page 14: ...ssing S till 0 appears in the left side of display Hold on pressing S till the 0 disappears from the display Press any key of the radio transmitter twice before the 0 disappears Now the coding procedu...

Page 15: ...put Light connection Power supply 230V Microchip Control unit Radio unit Photocells contact Plug for external control Photocells plug Microswitch encoder plug Display plug Motor plug Ground connection...

Page 16: ...ING DIAGRAM Optional devices WARNING Breaking the photocells beam while the door is closing immediatly stops the movement while it doesn t affect in opening COM OUT Control unit 12V R GND Photocells r...

Page 17: ...door reach the closed position as previously set and stops still TROUBLESHOOTING Problem Probable Cause Possible Solution The door doesn t move No radio transmitter code Code the radio transmitter aga...

Reviews: