22
2 - INSTALLATION
7.
SERIAL COM: Serial port with dip switches for insertion of 100ohm termina-
tion.
1 - CANH / LSA serial communication
2 - CANL / LSB serial communication
3 - 0V (GND).
4 - Power supply voltage (22V to 40V) available for serial port (if neces-
sary).
8.
GLOBAL EXCLUSION:
1. ESC-
2. ESC+
3.
4. ANALOG-
This function aims to reset the alarms coming from the feeders when
the machine stops. This function is similar to that of signals INC DEC,
when they switch the feeder from T1 with alarms enabled to T2 with
alarms disabled when the machine stops.
We have two options of operation, to achieve the same result:
1. ESC+ and ESC- (PIN 1 and 2) connected to the lamp: when the ma
chine stops, it switches on the signal lamp. This lamp applies a vol
tage between ESC+ and ESC- thus activating the exclusion.
In this condition, the machine does not consider any warning si
gnals possibly coming from the feeders.
2. and ANALOG- (PIN 3 and 4) connected to the machine
inverter: in this case a threshold shall be set using the trimmer 12.
Procedure: the operator has to turn the trimmer fully clockwise so
as to set the minimum threshold. After that, with a feeder in alarm
state, he starts the machine at a speed value below which the fee
der alarm must not be triggered. He finally turns the trimmer
clockwise until the feeder in alarm state stops the machine. That is
the sought threshold value.
9 & 10.
Leds (group 1 and group 2) for INC DEC and STOP signals.
- Led “D” = DEC signal. Led on when DEC enabled.
- Led “I” = INC signal. Led on when INC enabled.
- Led “S” = STOP signal. Led on when STOP enabled.
11.
Led Power ON and Fuse 15A Fast.
12.
Exclusion setting trimmer
ESC+ e ESC- :
from 5VDC to 40VDC
from 12VAC to 28VAC
e ANALOG -: from 0 to 10VDC