The Indoor Unit Installation
Installation Manual
17
ENGLISH
1) Indoor unit installation
■
Before Installing, prepare Installation Plates
•
'Installation Plates' are attached at the bottom
of indoor unit.
Detach them by removing each 3 screws at
both sides.
•
Detach 'Side Plate (R,L)' by removing each 2
screws on both sides.
•
Pull the upper right and left side of 'Inlet Grille'
to the front, and it will stop at slightly tilted
position.
•
Unhook the 'Inlet hanger' from the 'Hanger
screw' on the both left and right side.
•
Detach the 'Inlet Grille' from the Indoor Unit.
1) Installation on the ceiling
•
Measure and mark the position for the
Suspension bolts and the piping hole.
•
Drill the hole for anchor nut on the ceiling.
Before secure the Installation Plates,
select the bent direction of the
Installion Plate to the inside or the
outside according to the installation
circumstances.
•
Drill the piping hole on the wall slightly tilted
to the outdoor side using a
ø
70 hole-core
drill.
1076
Suspension
bolt
Center-line for the
piping hole
265
1236
265
Install Plate
1)
2)
5~7mm
Indoor
Outdoor
WALL
Side Plate
Inlet Grille
Inlet hanger
Hanger
screw
Summary of Contents for UU24
Page 43: ......