Installation of Indoor, Outdoor Unit
Installation Manual
7
ENGLISH
Convertible type
•
Do not have any heat or steam near the unit.
•
Select a place where there are no obstacles in
front of the unit.
•
Make sure that condensation drainage can be
conveniently routed away.
•
Do not install near a doorway.
•
Ensure that the interval between a wall and
the left (or right) of the unit is more than
70cm.
•
Use a stud finder to locate studs to prevent
unnecessary damage to the wall.
•
There should not be any heat source or steam
near the unit.
•
There should not be any obstacles to prevent
the air circulation.
•
A place where air circulation in the room will
be good.
•
A place where drainage can be easily
obtained.
•
A place where noise prevention is taken into
consideration.
•
Do not install the unit near the door way.
•
Ensure the spaces indicated by arrows from
the wall, ceiling, or other obstacles.
2. Outdoor unit
1. If an awning is built over the unit to prevent
direct sunlight or rain exposure, make sure
that heat radiation from the condenser is not
restricted.
2. Ensure that the spaces indicated by arrows
around front, back and side of the unit.
3. Do not place animals and plants in the path
of the warm air.
4. Take the air conditioner weight into account
and select a place where noise and vibration
are minimum.
5. Select a place so that the warm air and noise
from the air conditioner do not disturb
neighbors.
More than
70cm
More than
30cm
More than
70cm
More than
20cm
More than eye-level
More than
20cm
R
R
More than
20cm
More than
20cm
(Ceiling installation)
(Floor/Wall installation)
More than
30cm
More than 30cm
More
than 60cm
More than 60cm
More than
70cm