Installation of Indoor Unit
Installation Manual
29
ENGLISH
MARK
CHARACTERISTICS
MARK
CHARACTERISTICS
Closing valve
Manometer
Circulation pump
Temperature sensor
Closing valve with exhaust
Thermometer
Drain valve with plug
Consumer of heat / coolness
Water filter
Automatic vent
Expansion vessel
3-way switching valve with EM drive
Safety valve
M
3-way mixing valve with EM drive
Non-return valve
Supply pipe
Magnetic separator of impurities
Return line
Pipe safety thermostat
ELEMENTS
CONNECTING
TERMINALS
MARK
CHARACTERISTICS
1
Return for heating
2
Supply pipe for heating
PLC
Processing unit
PST
Pipe safety thermostat
Spatial
Connector on PLC
Q1-Q12
Digital outputs of regulation ~ 230 V (input/output module MD1 and MD2)
A1-A8
Analogue input (input/output module MD1 and MD2)
D1-D9
Digital input (input/output module MD1 and MD2)
MD1
Basic input/output module 1
T1
Thermostat of heating cycle 1
T2
Thermostat of heating cycle 2
OC1
Circulation pump of heating cycle 1
OC2
Circulation pump of heating cycle 2
MV2
Mixing valve of heating cycle 2
OGK-1
Heating cycle 1
OGK-2
Heating cycle 2
MD2
Expansion input/output module 2
T3
Thermostat of heating cycle 3
T4
Thermostat of heating cycle 4
OC3
Circulation pump of heating cycle 3
OC4
Circulation pump of heating cycle 4
MV3
Mixing valve of heating cycle 3
MV4
Mixing valve of heating cycle 4
OGK-3
Heating cycle 3
OGK-4
Heating cycle 4
The supply line of each heating cycle must be fitted with a pipe safety thermostat that is connected
sequentially with the circulation pump to safeguard against the inflow of high temperature.