Installation Manual
11
ENGLISH
General Information
Model name and related information
*1 : tested under Eurovent Heating condition
(water temperature 30 °C
’
35 °C at outdoor ambient temperature 7 °C / 6 °C)
*2 : tested under Eurovent Cooling condition
(water temperature 23 °C
’
18 °C at outdoor ambient temperature 35 °C / 24 °C)
*3 : All appliances were tested at atmospheric pressure.
Buyer Model Name
H
U
09
1
U
4
3
Serial Number
Platform (Chassis code)
3 : U3 Chassis
4 : U4 Chassis
Classification
U : Outdoor unit of Split type
Electrical ratings
1 : 1Ø, 220-240 V AC 50 Hz
3 : 3Ø, 380-415 V AC 50 Hz
Heating capacity (kW)
Ex ) 9 kW : ‘09’
U : Outdoor unit
Classification
H : Air to water Heat Pump
H
N
16
1
6
T
N
B
0
Serial Number
Platform (Chassis code)
B : DHW tank integrated
Classification
N : Indoor unit of Split type
T : DHW tank integrated
Heater capacity (kW)
Heater electrical ratings
1 : 1Ø, 220-240 V, 50 Hz
6 : 6 kW Heater
Heating capacity (kW)
Ex ) 16 kW : ‘16’
N : Indoor unit
Classification
H : Air to water Heat Pump
Model Name
Built-In Electric
Heater(kW)
Capacity
Power Source
Outdoor Unit
Indoor Unit
Heating(kW)
*1
Cooling(kW)
*2
AHUW146A2
AHNW16606B0
1Φ 4(2+2)
3Φ 6(2+2+2)
14.0
11.0
220-240 V ~ 50 Hz
AHUW096A3
9.0
9.0
AHUW126A3
12.0
10.4
AHUW146A3
14.0
11.0
AHUW166A3
16.0
12.0
AHUW128A3
12.0
10.4
380-415 V ~ 50 Hz
AHUW148A3
14.0
11.0
AHUW168A3
16.0
12.0