Chapter 3 - Quick Start Up
35
3.3.2
Frequency set by Keypad and Run/Stop by External Source.
1.
Connect wiring as shown below.
2.
Apply AC power.
3.
Confirm that the DRV 03 is set at ‘Fx/Rx-1’.
4.
Confirm that the DRV 04 is set at
‘Keypad-1’.
5.
Press
SHIFT/ESC
key.
6.
LCD:
Press
PROG
key.
7-Seg:
Press
PROG/ENT
key.
7.
LCD:
Set the frequency using
SHIFT/ESC
and
▲
key.
7-Seg:
Set the frequency by rotating the
encoder knob.
8.
LCD:
Press
ENT
key to save the data.
7-Seg:
Press
PROG/ENT
key to save the
data.
9.
Close the FX or RX contact to run the
motor.
10.
Open the FX or RX contact to stop the
motor.
LCD Display
7-Segment Display
P1 P2
JOG
CM
P3 FX RX NC
CM BX
RST
I
VR VI
FM 5G
DRV
►
T/K 0.0 A
00 STP 0.00Hz
The DRV LED is ON.
DRV
►
Drive mode
03 Fx/Rx-1
DRV
►
Freq mode
04 Keypad-1
DRV
►
T/K 0.0 A
00 STP 0.00Hz
DRV
►
Cmd. freq
00 0.00Hz
The PROG/ENT LED is turned ON.
DRV
►
Cmd. freq
00 60.00Hz
The PROG/ENT LED is turned ON.
DRV
►
T/V 0.0 A
00 STP 60.00Hz
The FWD or REV LED starts blinking. The RUN LED starts blinking.
The STOP/RESET LED starts blinking. The STOP/RESET LED starts blinking.