Chapter 4 - Options
44
Keypad Display
Setting Range
Code
Description
LCD
7-Segment
LCD
7-Segment
Units
Factory
Default
Adj.
During
Run
Page
FU1-51
10
Electronic Thermal Level
for 1 Minute
ETH 1 min
51
FU1-52 to 200 [%]
1 150
[%] Yes
FU1-52
Electronic Thermal Level
for Continuous
ETH cont
52
50 to FU1-51
1
100 [%]
Yes
Self-cool
0
FU1-53
Electronic Thermal
Characteristic Selection
(Motor Type)
Motor type
53
Forced-cool
1
- Self-cool
Yes
Text
mark
e
nicht
defini
ert.
FU1-54
Overload Warning Level
OL level
54
30 to 150 [%]
1 150
[%] Yes
FU1-55
Overload Warning Hold
Time
OL time
55
0 to 30 [sec]
0.1 10.0
[sec] Yes
Fehle
r!
Text
mark
e
nicht
defini
ert.
No
0
FU1-56
Overload Trip Selection
OLT select
56
Yes
1
- Yes
Yes
FU1-57
Overload Trip Level
OLT level
57
30 to 150 [%]
1 180
[%] Yes
FU1-58
Overload Trip Delay Time
OLT time
58
0 to 60 [sec]
1 60.0
[sec] Yes
Fehle
r!
Text
mark
e
nicht
defini
ert.
FU1-59
Stall Prevention Mode
Selection
Stall prev.
59
000 to 111
(Bit Set)
bit 000 No
FU1-60
Stall Prevention Level
Stall level
60
30 to 150 [%]
1 150
[%] No
Fehle
r!
Text
mark
e
nicht
defini
ert.
FU1-99
Return Code
Not displayed
99
Not available
[PROG/ENT]
or
[SHIFT/ESC]
- - -
Fehle
r!
Text
mark
e
nicht
defini
ert.
4.3
Function 2 Group [FU2]
Code
Description
Keypad Display
Setting Range
Units Factory
D f lt
Adj.
D ring
Page
10
Code FU1-51 through FU1-53 appears only when FU1-50 is set to ‘Yes’.