19
Addr
ess
NO.
Description
Default
Maximum
Minimum
Unit
5713 APP
#19
Aux start DT
600
9999
0
0.1sec
5714 APP
#20
Aux stop DT
600
9999
0
0.1sec
5715 APP
#21
Nbr Aux’
4
4
0
5716 APP
#22
Regul Bypass
0
1
0
5717 APP
#23
Sleep Delay
600
9999
0
0.1sec
5718 APP
#24
Sleep Freq
19
maxFreq
0
0.01Hz
5719 APP
#25
WakeUp level
35
100
0
1%
571A APP
#26
AutoCh_Mode 1 2 0
571B APP
#27
AutoEx intv
4320
5940
0
0.1sec
571C APP
#28
AutoEx level
20
100
0
1%
571D APP
#29
Inter-lock 0 1 0
571E APP
#30
Actual Value
0
maxFreq
0
0.01Hz
571F APP
#31
Actual Perc
0
100
0
1%
5720 APP
#32
Draw mode
0
3
0
5721 APP
#33
DrawPerc 100
150 0 1%
SV-iH
< DRV group >
Addr
ess
NO.
Description
Default
Maximum
Minimum
Unit
4001 DRV#01
Acc.
time
300
60000
0
0.1sec
4002 DRV#02
Dec.
time
600
60000
0
0.1sec
4003 DRV#03
Current
0
1
0
0.1
A
4004 DRV#04
Speed
0
1
0
1
rpm
4005 DRV#05
Power
0
5000
0
0.1kW
< FUN group >
Addr
ess
NO.
Description
Default
Maximum
Minimum
Unit
4101
FU1 #01
Freq. Set
0
2
0
4102
FU1 #02
Run/stop set
0
3
0
4103
FU1 #03
Run prohibit
0
2
0
4104
FU1 #04
Freq. Max
6000
40000
4000
0.01Hz
4105
FU1 #05
Freq. base
6000
Freq. max
4000
0.01Hz
4106
FU1 #06
Freq. start
50
500
50
0.01Hz
4107
FU1 #07
Hold time
0
100
0
0.1sec
Morek IT OÜ, Rauna 24, 76506 Saue Harjumaa, Estonia. www.morek.eu Tel. +372 604 1423 Fax +372 604 1447 [email protected]