Inspection
Check if there is any damage to the parts attached on the product or control devices during delivery or transportation.
Check if there is any problem for spare part or separately packed parts.
Environment Conditions
Check if the installation status or environment is the same as the table shown below.
Item
Specification
Remarks
Power supply
380Vac, 440Vac
It is the user's option.
May change depending on the power
supply of the customer.
Power Frequency
50/60Hz
It is the user's option.
Number of Power phase
3Phase
It is the user's option.
Control power
220/380/440Vac,3Ph
It is the user's option.
May change depending on power supply
of the customer
Controller power
20Vac,1PH,50/60Hz
Storage temperature
-10 °C ~ 60 °C
Working temperature
5 °C ~ 40 °C
Working humidity
25°C, 20% ~80%RH,
No dew condensation
Surrounding environment
No corrosive gas, flammable gas, oil
residue, dust, etc.
Elevation vibration
Altitude of 1000 m or below
5.9 m/sec²(=0.6g) or below
Controller contact Output capacity
Load below 250 Vac, 3 A, Available to
connect load below 30 Vdc, 1 A
- No-voltage "A" contact output
Controller contact Input capacity
Zero voltage contact input
- Power (20 Vdc, 10 mA) applied from
the controller.
- Do not apply power from the outside.
Momentary blackout
compensation
Controller : 100 mS or below