Installation
16
Indoor Unit
Group Control Setting
Master
GND
Signal
12 V
LGAP Network System
Master
Slave
Slave
Slave
Display Error Message
Only connect serial signal and GND lines
between indoor units.
or
1. Group Control 1
Wired remote controller 1 + Standard Indoor Units
Some products have no DIP switch on PCB. It is possible to set indoor units to Master or Slave by
using the wireless remote controller instead of DIP switch.
For the details of the setting, please refer to the manual of the wireless remote controller.
1. It is possible to 16 indoor units(Max.) by one wired remote controller.
Set only one indoor unit to Master, set the others to Slave.
2. It is possible to connect with every type of indoor units.
3. It is possible to use wireless remote controller at the same time.
4. It is possible to connect with Dry Contact and Central controller at the same time.
- The Master indoor unit is possible to recognize Dry Contact and Central Controller only.
5. In case that any error occurs at indoor unit, the error code is displayed on the wired remote
controller.
It is possible to control the other indoor units except the error units.
DIP Switch in PCB
Master Setting
- No. 3 Off
Slave Setting
- No. 3 On
Indoor Unit DIP Switch
Summary of Contents for MULTI V ARNU05GL4G4
Page 21: ...R32 R410A ...
Page 43: ......
Page 65: ...R32 R410A ...
Page 87: ......
Page 109: ...R32 R410A ...
Page 131: ......
Page 153: ...R32 R410A ...
Page 175: ......
Page 197: ......
Page 219: ......
Page 241: ......
Page 263: ......
Page 285: ......
Page 307: ......
Page 329: ......
Page 331: ......