16
Connecting the Device
Connecting Alarming Devices
The Alarm Terminals are used to connect the device with a
buzzer, alarm lamp, door switches or other external alarming
devices or relays.
The specification of the Alarm Terminal is as follows;
1
2
3
4
OUT
IN
GND
VCC
A
1
2
3
4
[Alarm Terminal Specification]
Minimum Typical Maximum Remarks
DC Output
2.9 V
3.1 V
3.3 V
Load Current
-
50 mA
100 mA
Digital Input
2.3 V
3.3 V
4.3 V
Digital Output
2.3 V
3.3 V
Cable Spec.
AWG 24
AWG 16
UL
Standard
0.20 mm
2
1.5 mm
2
IEC
Standard
• Absolute Maximum Ratings
-
Digital Input: -24 V to +24 VDC
-
Digital Ouput: +3 V to +24 VDC / 100 mA Max
Use the compatible cables to connect to the Alarm Terminal.
Press down for engagement, and press “A” Button to disengage.