INSTALLATION
ENGLISH
15
CAUTION
The power cord connected to the outdoor
unit should be complied with the follow-
ing specifications (Rubber insulation, type
H05RN-F approved by HAR or SAA).
If the supply cord is damaged, it must be
replaced by a special cord or assembly available
from the manufacturer or its service agent.
The connecting cable connected to the
indoor and outdoor unit should be com-
plied with the following specifications
(Rubber insulation, type H05RN-F
approved by HAR or SAA).
!
20mm
GN/YL
45±5
10±3
WARNING
Make sure that the screws of the termi-
nal are free from looseness.
!
Electricwire
Round crimp-style terminal
Attach insulation sleeve
Connect wires of the same gauge to both sides
Model
Normal
Cross-Sectional
LT-H282PLE0
3.5mm
2
(3 wires)
LT-H332NLE0
5.5mm
2
(3 wires)
LT-H452MLE0
LT-H512MLE0
6.5mm
2
(3 wires)
LT-C282PLE0
LT-C332NLE0
3.5mm
2
(3 wires)
LT-C452MLE0
LT-C512MLE0
6.5mm
2
(3 wires)
LT-C48BMLE0
LT-C52BMLE0
3.5mm
2
(4 wires)
Model
Normal
Cross-Sectional
LT-H282PLE0
LT-H332NLE0
0.75mm
2
(5 wires)
LT-H452MLE0
LT-H512MLE0
1.0mm
2
(5 wires)
LT-C282PLE0
LT-C332NLE0
0.75mm
2
(4 wires)
LT-C452MLE0
LT-C512MLE0
LT-C48BMLE0
LT-C52BMLE0
1.0mm
2
(4 wires)
20mm
GN/YL
45±5
10±3