5-16
CHECKING FLOW CHART BY FAILURE MODE
Replace the Sensor
Check the thermistor using the test mode 4.
Diagnosis
Oven sensor.
After value the sensor value are 70˚F~90˚F(at 24˚C)
Check the thermistor’s resistor
CN04 pin3, 4
Normal: approximately 1.09 k
Ω
Power Off
Is the value OK?
No
Yes
Is the value OK?
Replace the system PCB
END
No
Yes
Oven Thermistor failed(including F-1, F-2 error)
oven sensing failed
(including sensor error)
Summary of Contents for LSWS305ST
Page 51: ...6 1 SCHEMATIC DIAGRAM ...
Page 54: ...6 4 Bake Roast mode Self Clean mode ...
Page 55: ...6 5 Warm Proof mode ...
Page 58: ... 7 3 EV CONTROLLER PARTS 2381 2050 2006 2119 2009 2118 W108 W105 W105 W258 ...