Resistor
Min
Max
Bake
22.0
35.0
Convection
25.0
42.0
Inner broil
22.0
35.0
Outer broil
35.0
46.0
5-11
CHECKING FLOW CHART BY FAILURE MODE
Oven does not heat (including F-9 error)
Measure the Resistor of each heater
Between the DLB Relay’s L2 and
each heater Relay’s Harness point of Figure 1
(
①, ②, ③, ④
and
⑤
)
(measure the resistance after cooling down)
Normal:
Figure 1
L2
Bake
Bake
Bake
Bake
Bake
Bake
Bake
Bake
Bake
Bake
Bake
Bake
Bake
Bake
Bake
Bake
Bake
Bake
Inner Broil
Inner Broil
Inner Broil
Inner Broil
Inner Broil
Inner Broil
Inner Broil
Inner Broil
Inner Broil
Inner Broil
Inner Broil
Inner Broil
Inner Broil
Inner Broil
Inner Broil
Inner Broil
Inner Broil
Inner Broil
Convection
Convection
Convection
Convection
Convection
Convection
Convection
Convection
Convection
Convection
Convection
Convection
Convection
Convection
Convection
Convection
Convection
Convection
Out Broil
Out Broil
Out Broil
Out Broil
Out Broil
Out Broil
Out Broil
Out Broil
Out Broil
Out Broil
Out Broil
Out Broil
Out Broil
Out Broil
Out Broil
Out Broil
Out Broil
Out Broil
If it is not correct,
Measure heater resistance directly.
Is resistor value OK?
END
No
Yes
Replace the error heater
2
1