4-3
Oven Thermistor
Door switch
Oven lamp
1. Refer to page 3-5 for disassembly
2. Measure the resistance after cool down
(Multiple meter scale: R x 1000)
Components
Test procedures
Results
1. Refer to page 3-5 for disassembly
2. Measure the resistance after cool down
(Multiple meter scale: R x1)
Normal: Approximately
1090
Ω
Replace if: Infinite (opened)
below 10
Ω
(shorted)
Door open
Door closed
Continuity
Infinite
NOTE:
After checking for the continuity of switch, make sure to reconnect leads
properly.
1. Refer to page 3-7 for disassembly
2. Measure the resistance after cooling down
(Multiple meter scale: R x 1)
NOTE:
Ω
Value should be
tested at room temperature
(77F/25˚C)
Normal: Below 5
Ω
.
Replace if: Infinite