5-15
CHECKING FLOW CHART BY FAILURE MODE
lock system failure(including F-10 error)
OK?
Yes
No
Replace the locking motor
END
Is the connection OK?
Yes
No
OK?
Yes
No
OK?
Yes
Fix the connection
Replace the Relay PCB
Replace the System PCB
Check the Relay PCB’s electric connection (CN01, CN03)
Check the connection between system
PCB and relay PCB(CN11)
END
END
Check the loose connector (Oven main PCB CN08)
Check the locking motor (measure the resistance)
Normal : approximately 2.6 k
Ω
Abnormal : infinite or below 5
Ω