![LG LRSXC2306 Series Service Manual Download Page 67](http://html.mh-extra.com/html/lg/lrsxc2306-series/lrsxc2306-series_service-manual_1902100067.webp)
7. Poor cooling in Freezer compartment
1. Poor cooling in
Symptom
Check Point
Freezer compartment
1. Check the sensor resistance
2. Check the air flow
3. Check the air temperature
4. Check the R-Damper
5. Check the Fan motor sticky
6. Check the Fan motor voltage
Duct
Status
Air Flow
Windy
Air Temperature
Cold
CON
4
17
th
pin ~
18
th
pin
Resistance
[Ω]
-22ºF / -30ºC
40k
-13ºF / -25ºC
30k
-4ºF / -20ºC
23k
5ºF / -15ºC
17k
14ºF / -10ºC
13k
23ºF / -5ºC
10k
32ºF / 0ºC
8k
TEST MODE 1
Voltage
[V]
CON
3
13
th
pin ~ 1
6
th
pin
10
.8
~1
3.2
VDC
CON
3
13
th
pin ~ 1
5
th
pin
2~4.5 VDC
CON
3
13
th
pin ~ 1
4
th
pin
Not 0V, 5V