![LG LRSXC2306 Series Service Manual Download Page 45](http://html.mh-extra.com/html/lg/lrsxc2306-series/lrsxc2306-series_service-manual_1902100045.webp)
Troubleshooting
TEST MODE 1
Voltage [V]
CON9
7
nd
pin ~ 13
th
pin
0V
Defrost Heater Error
(
F dH)
1
Replace the
Door gasket
Check the Door gasket .
Is door gasket damaged?
Yes
No
2
Check the Defrost control part.
(2) Is Defrost Heater resistance
39 ~ 44Ω?
No
Yes
Change
Fuse-M
4
Check the Heater Voltage.
Is voltage 112~116V?
Yes
3
Check the Defrost control part.
Is Defrost Sensor resistance
22k
Ω↑ or OFF?
OFF
22kΩ
Replace
product
Input Test 2 Mode
(Push the button 2 times)
Replace
Main PCB
NO
TEST MODE 2
Voltage [V]
CON9
7
nd
pin ~ 13
th
pin
120V
5
Check the Heater Voltage.
Is voltage 0V?
Yes
Input Test 1 Mode
(Push the button 1 time)
Replace
Main PCB
No
6
Explain to customer
46
Copyright © 20 21 LG Electronics Inc. All rights