![LG LRSXC2306 Series Service Manual Download Page 49](http://html.mh-extra.com/html/lg/lrsxc2306-series/lrsxc2306-series_service-manual_1902100049.webp)
Troubleshooting
Condenser Fan Error ( E CF)
1
2
Check the fan rotating.
Does fan rotate?
No
Yes
Go to 3
3
Check the Fan motor.
Rotate fan using hand.
It feel sticky?
Yes
Change the
Fan motor
Reset the unit and
Input Test1 Mode.
(Push the button 1 time)
Go to 4
Fan Motor
Fan Motor
TEST MODE 1
Voltage [V]
CON3
9
th
pin ~ 11
th
pin
2~4.5 VDC
4
Check the Fan Motor voltage
Is Fan Motor voltage 10 ~ 12 V?
Yes
Replace
Main PCB
No
TEST MODE 1
Voltage [V]
CON3
9
th
pin ~ 12
th
pin
5
Check the Fan Motor voltage
Is Fan PWM voltage 2~4.5V ?
Yes
Replace
Main PCB
No
6
Explain to customer
TEST MODE 1
Voltage [V]
CON3
9
th
pin ~ 10
th
pin
Not 0V, 5V
5
Check the Fan Motor voltage
Is Fan Feed Back voltage 0V,5V ?
No
Change the
motor
Yes
50
Copyright © 20 21 LG Electronics Inc. All rights
reserved. Only training and service purposes.
10 ~ 12 V?