![LG LRSXC2306 Series Service Manual Download Page 5](http://html.mh-extra.com/html/lg/lrsxc2306-series/lrsxc2306-series_service-manual_1902100005.webp)
-5-
Comp Trip Summary
Copyright © 2021 LG Electronics Inc. All rights
reserved. Only training and service purposes
■
Protection Logic
Recipro BLDC
(BMA & BMG series)
Linear Compressor
(Before FLA150NBMA)
Linear Compressor
(After FLA150NBMA)
Protection
LED
Purpose
Trip name
LED
Purpose
Trip name
LED
Purpose
FCT0
(Short Circuit)
1
Micom Sensing
Circuit problem
decision
FCT0
1
Micom Sensing
Circuit problem
decision
FCT0
1
Micom Sensing
Circuit problem
decision
OverVoltage Trip
2
DC Link
OverVoltage
Detect
Stroke Trip
2
Over Stroke
Detect
Stroke Trip
2
Stroke error
detect
No Connect Trip
3
Comp Harness
no connect deteft
OverVoltage Trip
4
DC Link
OverVoltage
Detect
Pistion Lock
5
Piston Lock
detect
Pistion Lock
5
Piston Lock
detect
Over Current
Detection
6
Over Current
detect
Current
Detection
6
Over Current
detect
Current
Detection
6
Over Current
detect
Fault(Fo)
7
IPM armshort
detect
(IPM Fault
detect)
Fault(Fo)
7
IPM armshort
detect
(IPM Fault
detect)
Fault(Fo)
7
IPM armshort
detect
(IPM Fault
detect)
Communication
Error
8
Communication
Error
Communication
Error
8
Communication
Error
Communication
Error
8
Communication
Error
Remark: When 1 trip occurs, keep it
permanently until power OFF
After ‘19 Year Model, When the
trip occurs, the LED lights the
same as before. Comp. OFF signal
(intermittent, defrost) LED is initialized.
Remark: When 1 trip occurs, keep it
permanently until power OFF
Remark: When the trip occurs, the
LED lights the same as before. Comp.
OFF signal (intermittent, defrost) LED
is initialized.