![LG LRSXC2306 Series Service Manual Download Page 58](http://html.mh-extra.com/html/lg/lrsxc2306-series/lrsxc2306-series_service-manual_1902100058.webp)
5
Explain to customer
3
Check the resistance value.
Is Pilot Valve resistance
390~450
No
Yes
Replace
Water Valve
Pilot Valve
Valve
Resistance [Ω]
Pilot Valve
390~450
4
Check the resistance value.
Is Water Valve resistance
360~390
No
Yes
Replace
Water Valve
Water Valve
Valve
Resistance [Ω]
Water valve
330~390
INSPECTION
POINT
Water
LEVER S/W
Pilot Valve
CON
1
8
nd
pin ~ 11
th
pin
Pushing
19.2 ~ 28.8V
Not
Pushing
0~2V
Water
Valve
CON
1
4
nd
pin ~ 1
2
th
pin
Pushing
19.2 ~ 28.8V
Not
Pushing
0~2V
Water mode doesn’t work
2
Check the voltage.
(while pushing the lever S/W)
Is voltage correct compared with
table?
No
Yes
1
Check the loose connection
3
Check the voltage. Valves voltage
correct compared with table?
No
Yes
Change the
PCB
Change the
PCB
INSPECTION POINT
LEVER
S/W
RESULT
ICE/Water Lever SW
CON
2
5
th
pin ~
6
th
pin
Pushing
0~2V
Not
Pushing
3.5~5V
60
Copyright © 20
21
LG Electronics Inc. All rights
reserved. Only training and service purposes.