![LG LRSXC2306 Series Service Manual Download Page 38](http://html.mh-extra.com/html/lg/lrsxc2306-series/lrsxc2306-series_service-manual_1902100038.webp)
Troubleshooting
3. Room Temperature Sensor Error
1. Check for a loose connection
2. Check Sensor Resistance
1. Ert
Symptom
Check Point
Resistance [Ω]
CON7
17
th
pin ~ 18
th
pin
Short
0
Open
OFF
Other
Normal
Resistance
[ohm]
23ºF / -5ºC
38k
32ºF / 0ºC
30k
41ºF / 5ºC
24k
50ºF / 10ºC
19.5k
59ºF / 15ºC
16k
39
Copyright © 20
21
LG Electronics Inc. All rights
reserved. Only training and service purposes.
CON7
17
th
pin ~ 18
th
pin