100
-
11-2 Check B
1. FCT0 Trip and LED Blinking 1 time (FCT0 Fault)
→
Purpose : To detect the compressor voltage and current sensing error.
→
Restart every 30 seconds after compressor off.
Blink
OFF Blink OFF
2. Stroke Trip and LED Blinking 2 times (Stroke Trip)
Blink
Blink OFF Blink Blink OFF
Y
Y
Y
Check
the Protection Logic
Check Stroke or
LED Blinking 2 times
(Stroke Trip)
Do not operate
Comp.?
Y
N
Compressor is operate
intermittently
Check Comp.
Replace
Compressor
N
Reset
Stroke Trip
occur?
Check the
leakage and cycle
Y
Recheck
Check
Harness connection
Repair Harness
N
N
→
Purpose : Protection piston crash by abnormally large Stroke.
→
Case 1. Do not operate Comp.
: harness connection failure between the PCB, Comp, Capacitor.
→
Case 2. Do operate Comp. intermittently
: Condenser Fan or Freezer Fan Error.
System Error like water-clogging, capillary-clogging, refrigerant-leakage
→
Logic: After the Comp. Off every 1 minute restart Comp.
LED 1
Blinks
Replace PCB
LED 1
Blinks
About 5min
Reset
Test
Mode
1 Input