-
90
-
0Q
%JGEMKPI(NQY
4GUWNV58%#EVKQP
ඖ
%JGEMVJG(TGG\GTFQQTUYKVEJ
The Switch senses if the door is open or close.
.When the door open, lamp On
.When the door Close, lamp Off
ȉ
close Door and check the lamp Through the gap
ඖ
Check Voltage Between
CON3 30th pin
and 29th pin
3
ඖ
Check the Reed S/W resistance
-.No Magnet
-.Magnet Near the Switch
-.Resistance & Service Action
-.Magnet must be center of Switch
Magnet Center
Switch Center
(O)
Good position
Bad position
(X)
Magnet Center
Switch Center
,QFDVHRI
6WDWXV
5HVXOW
69&$FWLRQ
'RRU &ORVH
9Ȥ
&KHFN 5HHG6:
&KHFN +DUQHVV
disconnection
,I 1RRNFKDQJH 3&%
,QFDVHRI
'RRU 2SHQ
9
1.Check Reed S/W
2.Check Harness disconnection
3.If No.1,2 ok ,change PCB
2
2
j vuZ
10-
3
-
2
Door Switch,F
Copyright © 2019 LG Electronics Inc. All rights
reserved. Only training and service purposes.