10
1
-
3. No Connect Trip and LED Blinking 3 times (No Connection Trip)
Blink
Blink
OFF
Blink
Blink
OFF
Y
Y
Check
the Protection Logic
Check
No Connect or
LED blinking 3 times
(No Connect Trip)
Do not operate
Comp.?
Y
N
Check Comp.
Replace
Compressor
N
Reset
No Connect Trip
occur?
Replace PCB
Y
Recheck
Check
Harness connection
Repair Harness
N
N
→
Purpose : Prevention Over-Voltage and Over-Current by detecting connection error check.
→
Cause : harness connection failure between PCB, Comp, Capacitor.
Comp. insulation breakdown.
→
Logic : After the Comp. Off every 40 seconds restart Comp.
Blink Blink
Copyright © 2019 LG Electronics Inc. All rights
reserved. Only training and service purposes.