-5
2
-
Condenser Fan Error (Er CF)
1
2
Check the fan rotating.
Does fan rotate?
No
Yes
Go to 3
3
Check the Fan motor.
Rotate fan using hand.
It feel sticky?
Yes
Change the
Fan motor
Reset the unit and
Input Test1 Mode.
(Push the button 1 time)
Go to 4
Fan Motor
Fan Motor
Voltage [V]
Not 0V, 5V
Check the Fan Motor voltage
Is Fan Motor voltage
11.4~12.6
V?
Yes
Replace
Main PCB
No
Voltage [V]
11.4~12.6V
Check the Fan Motor voltage
Is Fan PWM voltage 0V, 5V?
No
Change the
motor
Yes
7
Explain to customer
Voltage [V]
Not 0V, 5V
Check the Fan Motor voltage
Is Fan Feed Back voltage 0V, 5V?
No
Yes
4
6
5
Replace
Main PCB
TEST MODE 1
CON3
12th pin ~ 9th pin
TEST MODE 1
CON3
10th pin ~ 9th pin
TEST MODE 1
CON3
11th pin ~ 9th pin
Copyright © 2019 LG Electronics Inc. All rights