- 25 -
■
Auto Restarting Operation
• When the power is restored after a sudden power failure while in appliance operation, the mode before the
power failure is kept on the memory and the appliance automatically operates in the mode on the memory.
• The slide switch on the main unit of the appliance should be on the Auto Restarting position in order that
the Auto Restarting operation is available.
• Operation Mode that is kept on the memory
- State of Operation ON/OFF
- Operation Mode/Setting Temp/Selected Airflow Speed
- Sleep Timer Mode/Remaining Time of Sleep Timer (unit of hour)
Slide Switch
FORCED
OPERATION
AUTO
RESTART
REMOTE
CONTROL
■
Forced Operation (C/O Model)
• To operate the appliance by force in case that the remote control is lost, the forced operation selection
switch is on the main unit of the appliance to operate the appliance in the standard conditions.
• When the power is supplied while the slide switch is on the forced operation position, or when the slide
switch position is switched to the Auto Restarting position (or test operation) or switched from the remote
control position to the forced operation position while the power is on, the forced operation is carried out.
• When the slide switch position is switched from the forced operation position to the Auto Restarting position
or the remote control position, the forced operation is canceled and the appliance stops operating.
• The forced operation is carried out in cooling mode with the setting temperature 22°C and the high speed of
airflow.
■
Forced Operation (H/P Model)
• To operate the appliance by force in case that the remote control is lost, the forced operation selection
switch is on the main unit of the appliance to operate the appliance in the standard conditions.
• When the power is supplied while the slide switch is on the forced operation position, or when the slide
switch position is switched to the Auto Restarting (or test operation) position or switched from the remote
control position to the forced operation position while the power is on, the forced operation is carried out.
• When the slide switch position is switched from the forced operation position to the Auto Restarting position
or the remote control position, the forced operation is canceled and the appliance stops operating.
• The forced operation is carried out in cooling mode with the setting temperature 22°C and the high speed of air-
flow.
• In the forced operation mode, the indoor fan is operated at low speed for around 15 sec and then the oper-
ation condition is set according to the intake air temperature as follows.
24°C
≤
Intake Air Temp
➲
Cooling Mode Operation, 22°C, High Speed
21°C
≤
Intake Air Temp<24°C
➲
Dehumidification Operation, 23°C, High Speed
Intake Air Temp<21°C
➲
Heating Mode Operation, 24°C, High Speed
Summary of Contents for LM-2422A2L/A3L
Page 12: ... 12 900 1 225 370 2 3 LM 4822C3L LM 4822A3L ...
Page 60: ... 60 3 Display Assembly ...
Page 62: ... 62 1 2 LM 3620C2L LM 3622A2L LM 3620A2L ...
Page 63: ... 63 2 Outdoor 2 1 LM 2422C2L LM 2422A2L ...
Page 64: ... 64 2 2 LM 3625C3L A3L LM 3626A3L ...
Page 65: ... 65 2 3 LM 4822C3L LM 4822A3L ...
Page 81: ...P No 3828A20095K January 2005 Printed in Korea ...