Functions
• Room temperature sensor. (THERMISTOR)
• Maintains the room temperature in accordance with the Setting Temp.
• Indoor fan is delayed for 5 seconds at the starting.
• Restarting is inhibited for approx. 3 minutes.
• High, Med, Low, Chaos
--- Lights up in operation
--- Lights up in Sleep Mode
--- Lights up in Timer Mode
--- Lights up in Deice Mode(for Heat pump model)
--- Lights up in Compressor operation(for Cooling model)
• Intermittent operation of fan at low speed.
• The fan is switched to low(Cooling), med(Heating) speed.
• The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
• The fan is switched to intermittent or irregular operation
• The fan speed is automatically switched from high to low speed.
• The louver can be set at the desired position or swing
up and down automatically.
Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
Room temperature control
Starting Current Control
Time Delay Safety Control
Indoor Fan Speed Control
Operation indication Lamps (LED)
OUT
DOOR
Health Dehumidification Operation
• Both the indoor and outdoor fan
stops during deicing.
• Hot start after deice ends.
• The indoor fan stops until the
evaporator piping temperature will be
reached at 22°C.
Sleep Mode Auto Control
Natural Air Control by CHAOS Logic
Airflow Direction Control
Deice (defrost) control (Heating)
Hot-start Control (Heating)
Summary of Contents for LM-2422A2L/A3L
Page 12: ... 12 900 1 225 370 2 3 LM 4822C3L LM 4822A3L ...
Page 60: ... 60 3 Display Assembly ...
Page 62: ... 62 1 2 LM 3620C2L LM 3622A2L LM 3620A2L ...
Page 63: ... 63 2 Outdoor 2 1 LM 2422C2L LM 2422A2L ...
Page 64: ... 64 2 2 LM 3625C3L A3L LM 3626A3L ...
Page 65: ... 65 2 3 LM 4822C3L LM 4822A3L ...
Page 81: ...P No 3828A20095K January 2005 Printed in Korea ...