2-way Valve (Liguid Side)
3-way Valve (Gas Side)
Works
Shaft position
Shaft position
Service port
Shipping
Closed
Closed
Closed
(with valve cap)
(with valve cap)
(with cap)
Air purging
Open
Closed
Open
(Installation)
(counter-clockwise)
(clockwise)
(push-pin or with
vacuum pump)
Operation
Open
Open
Closed
(with valve cap)
(with valve cap)
(with cap)
Pumping down
Closed
Open
Open
(Transfering)
(clockwise)
(counter-clockwise)
(connected
manifold gauge)
Evacuation
Open
Open
Open
(Servicing)
(with charging
cylinder)
Gas charging
Open
Open
Open
(Servicing)
(with charging
cylinder)
Pressure check
Open
Open
Open
(Servicing)
(with charging
cylinder)
Gas releasing
Open
Open
Open
(Servicing)
(with charging
cylinder)
- 46 -
2-way, 3-way Valve
3.
2.
1.
4.
5.
6.
Flare nut
To
piping
connection
Open position
Closed position
Flare nut
Valve cap
To
piping
connection
Open position
Closed position
Hexagonal wrench
(4mm)
To outdoor unit
Pin
Service
port
Service
port cap
To outdoor unit
Summary of Contents for LM-2422A2L/A3L
Page 12: ... 12 900 1 225 370 2 3 LM 4822C3L LM 4822A3L ...
Page 60: ... 60 3 Display Assembly ...
Page 62: ... 62 1 2 LM 3620C2L LM 3622A2L LM 3620A2L ...
Page 63: ... 63 2 Outdoor 2 1 LM 2422C2L LM 2422A2L ...
Page 64: ... 64 2 2 LM 3625C3L A3L LM 3626A3L ...
Page 65: ... 65 2 3 LM 4822C3L LM 4822A3L ...
Page 81: ...P No 3828A20095K January 2005 Printed in Korea ...