Summary of Contents for AAF AstroPure 500 IR

Page 1: ...1 AstroPure Portable Air Purification System INSTALLATION OPERATION AND MAINTENANCE MANUAL...

Page 2: ...Calculation 12 EC Motor Speed Adjustment 13 Operating Instructions 13 Internal Fuse 13 Internal Kill Switch 13 Wiring Diagram 14 Maintenance Service 15 Filter Replacement 16 Replacement Parts 20 Contr...

Page 3: ...ures with your company s safety personnel Precautions Warnings Failure to follow these instructions properly may result in injury or loss of life Failure to follow these instructions properly may resu...

Page 4: ...e sticks are present Fire or smoke may result from ignition or suction toward the unit Do not use near a smoke detector If exhaust air flows in the direction of a smoke detector the smoke detector may...

Page 5: ...accordance with all applicable codes and standards including fire rated construction h Follow the heating equipment manufacturer s guideline and safety standards such as those published by the Nationa...

Page 6: ...r instruction concerning operation of the unit by a person responsible for their safety c Children should be supervised to ensure that they do not play with the unit d People who are intoxicated or ha...

Page 7: ...Portable Unit Air Exhaust 0 1000CFM Integrated PM Sensor High capacity Energy Savings High capacity HEPA 99 99 0 3 Micron Two stage filtration technology MERV 11 prefilter HEPA filter 99 99 capture e...

Page 8: ...6x16x4 HEPA Filter 99 99 18x18x12 18x18x12 18x18x12 18x18x12 Motor Type EC Motor Power HP 0 33 0 33 1 1 Max Current Draw A 7 7 15 15 Blower Type Impeller Forward Curved Impeller Forward Curved Impelle...

Page 9: ...move the equipment from the shipping carton and inspect for any damage that may have occurred during transportation Two workers at minimum are required to lift the unit from the container 2 Remove uni...

Page 10: ...60Hz outlet Install in accordance with all local state and nation electrical codes Important Note The equipment is plug and play and requires minimum conditions for normal operation A standard 9 ft 3m...

Page 11: ...djustments 4 When the power cord is plugged into a wall receptacle and the power switch is ON the control panel HMI will sound an audible confirmation and illuminate 5 The system starts with the fan i...

Page 12: ...inimum recommended 2 ACH then the recommended CFM for the unit would be CFM 10 x 35 x40 x 2ACH x 1hr 60min 466CFM NOTE ASHRAE recommends a minimum of 2 ACH for re opening schools for example The follo...

Page 13: ...use holder from the cabinet mounted fuse housing Check for blown fuses if control panel does not illuminate when the unit is powered on Internal Kill Switch An internal kill switch has been installed...

Page 14: ...motor 1 HP 11 45 Amp 115 120 V 50 60 Hz 1phase 15 Amp fuse Rotation counter clockwise Motor must start at 1 0 2 VDC 10 PWM AT 600 10 RPM AstroPure 500 EC motor 0 33 HP 4 4 Amp 115 120V 50 60 Hz 1 pha...

Page 15: ...Please refer to local federal regulations for PPE guidance Similarly handle dirty filters with extreme caution and local national guidelines To replace the pre filters HEPA filters please proceed acco...

Page 16: ...u will see the HEPA and Pre filters Figure 3 MEGAcel I eFRM 18 x 18 x 11 PN 905 301 090 1 unit VariCel 2 HC NH 16 x 16 x 4 PN 3102040 609 1 unit Note If your equipment has the knob retention brackets...

Page 17: ...tep A Identify the brackets Step B Remove the Brackets Left and Right Slide the bracket to the side forward or backward depending on your model then pull tto remove Check the model to determine the br...

Page 18: ...se Install Remove the HEPA filter by sliding it into the upper filter track Figure 9 Be sure that the sealing gasket is located on the air outlet side of the equipment This is the side closest to the...

Page 19: ...remove use your hands to loosen the knob by turning counterclockwise Figure 11 Install Remove the pre filter by sliding it into the lower filter track Figure 12 Check to ensure the airflow arrow posit...

Page 20: ...refilter can last up to six 6 months depending on the indoor air contamination levels It is recommended to replace it over an interval of four to six 4 6 months HEPA Filters The HEPA filter can last u...

Page 21: ...21 Control Panel Screen Overview Button Names CONTROL PANEL CONT D Control Panel Screen Overview Startup Screen...

Page 22: ...22 CONTROL PANEL CONT D Control Panel Screen Overview Filter s Pressure Drop and Particulate Matter Counting Screen Control Panel Screen Overview Main Screen...

Page 23: ...23 CONTROL PANEL CONT D Control Panel Screen Overview Decontamination Cycle Standby PM Indicator Alert Control Panel Screen Overview Schedule Programming...

Page 24: ...rticle size After you selected the particle size return to the main screen to view the results Reset the Filter Life timer After replacing the filter On the PM and Filter Pressure Drop press and hold...

Page 25: ...on field When set to Yes the PM level will appear on the main screen When set to No the filter pressure drop will appear on the main screen Set PM Alert function On the PM and Filter Pressure Drop pre...

Page 26: ...n speed set point To cancel a manual Decontamination cycle repeat the procedure that will disable the function Note The Decontamination Cycle is intended to provide fast recovery and or reduce the roo...

Page 27: ...ther prefilter or HEPA filter require replacement Increase speed setting on the control panel NOTE Increasing speed can lead to a higher noise level Categories Values PM 2 5 g m Good 0 0 12 0 These me...

Page 28: ...l and re installation of such product s or goods including but not limited to labor service costs and shipping charges The same obligations and conditions shall extend to replacement parts furnished b...

Page 29: ...n B 03 25 2021 Revision B adding new information about control panel C 09 14 2021 Adding new information about control panel and sound levels D 09 10 2023 Add appendix A and B about the installation o...

Page 30: ...AAF Air Filtration Product Solutions Americas Louisville KY Atlanta GA Ardmore OK Bartow FL Columbia MO Fayetteville AR Smithfield NC Tijuana Mexico Votorantim Brazil Washington NC Europe Cramlington...