58
TROUBLESHOOTING
Problem
Possible Cause
Solutions
indicator light is on
during the drying cycle
Water supply error.
Check steam feeder drawer:
(1) Make sure the steam feeder is filled
with water to the MAX line.
(2) Make sure the steam feeder is seated
properly and the drawer is fully closed.
(3) Turn the dryer off then restart the
STEAM CYCLE.
Do not use distilled water; the water level
sensor in the steam generator will not
work.
Pump not working.
Unplug dryer and call for service.
The display shows d80,
d90, d95
The duct work is about 80%-95%
blocked.(“d80”,“d90” or “d95”
error code is displayed for 2
hours only)
House exhaust system blocked.
Do not use the dryer until the exhaust
system has been cleaned and/or repaired.
Using the dryer with a severely restricted
exhaust is dangerous and could result in
a fire or other property damage.
Check the outside dryer vent while the
dryer is operating to make sure there is
strong airflow.
If the exhaust system is extremely long,
have it repaired or rerouted.
Keep the area around the dryer clean and
free of clutter.
Check vent hood for damage or lint
clogging.
Make sure the area around the vent hood
is clear.