32
INSTALLATION
Installation Test (Duct Check)
Once you have completed the installation of the
dryer, use this test to make sure the condition of the
exhaust system is adequate for proper operation of
the dryer. This test should be performed to alert you
to any serious problems in the exhaust system of
your home.
•
Your dryer features Flow Sense™, an innovative
sensing system that automatically detects
blockages and restrictions in dryer ductwork.
Keeping ductwork clean of lint buildup and free of
restrictions allows clothes to dry faster and reduces
energy use.
NOTE
The dryer should be cool before starting this test.
If the dryer was warmed up during installation, run
the AIR DRY cycle for a few minutes to reduce
the interior temperature.
To activate the installation test:
1
Remove the drying rack and literature, and
then close the door.
Do not load anything in the drum for this test, as
in may affect the accuracy of the results.
2
After you are pressed of Power button, you
will press and hold the Temp. and Signal
buttons in 3 seconds.
This button sequence activates the installation
test. The code
will display if the activation
is successful.
3
Press the START/PAUSE button.
The dryer will start the test, which will last about
2 minutes. The heat will be turned on and the
temperatures in the drum will be measured.
4
Check the display for results.
During the test cycle, monitor the Flow Sense™
display on the control panel. If no bars are
displayed, when the cycle ends, the exhaust
system is adequate. If the exhaust system is
severely restricted, the display will show four
bars. Other problems may also be shown with
error codes. Refer to the next page for error
code details and solutions.
NO BARS:
OK
FOUR BARS:
RESTRICTED
Four bars indicates that the exhaust system is
severely restricted. Have the system checked
immediately, as performance will be poor.
5
End of cycle.
At the end of the test cycle,
will display.
The test cycle will end and the dryer will shut off
automatically after a short delay.
•
Check the error code before you call for service
Error
Code
Possible
Causes
Solutions
tE1 or
tE2
•
Temperature
sensor failure.
•
Turn off the dryer and
call for service.
HS
•
Humidity
sensor failure.
•
Turn off the dryer and
call for service.
PS or
PF or
nP
•
Electric dryer
power cord is
not connected
correctly, or
house power
supply is
incorrect.
•
House fuse is
blown, circuit
breaker has
tripped, or
power outage
has occurred.
•
Check the power
supply or the
connection of the
power cord to the
terminal block. Refer
to the
Connecting
Electric Dryers
section of this
manual for complete
instructions.
•
Reset circuit breaker
or replace fuse. Do
not increase the fuse
capacity.
If the problem is a
circuit overload, have it
corrected by a qualified
electrician.
gAS
•
Gas supply or
service turned
off. (Gas
Model only.)
•
Confirm that house
gas shutoff and the
dryer gas shutoff are
both fully open.