3-20
3. FLD DISPLAY CHECK
ELECTRICAL TROUBLESHOOTING GUIDE
FLD DISPLAY CHECK
OK
Check and change D301.
Check and change
Q301, Q303, Q305, Q306.
If voltage is not 3.3 V.
Check output data R305, R304,
R303.
Replace IC300.
Refer to MPEG troubleshooting.
Replace IC300.
FLD light on?
OK
OK
Refer to SMPS/MPEG
troubleshooting.
Check
PN100 pin1 input
voltage 5 V.
Check D301
input votltage 5 V?
Check T300
pin6, 7 Output votltage AC 2.6 V.
Check D302 pin1 Output
votltage -27 V.
Check
IC300(PT6315) voltage
pin30 VKK: -27 V
pin13, 43: 3.3 V.
Check IC300
data communication
STB/DATA/CLK.
Check IC300.
Check IC300.
Check input data
PN100 pin6, 7, 8.
NO
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES