3-9
< Signal check point >
IC801
IC801
ONE POINT REPAIR GUIDE
NO OPERATION OF MD
When no sound output in the CD function, you can not listen to music reading data from a CD disc if
the pickup module in MD doesn’t work. This step is for checking the LASER TRACKING ACTUATOR.
4-4. LASER TRACKING ACTUATOR
4-4-1. Solution
Please check and replace IC800, IC801 on MAIN board.
4-4-2. How to troubleshoot (Countermeasure)
The tracking actuator makes the laser beam be positioned in the center of a track on CD disc.
1) Check the TDOUT signal from pin14 of IC801.
If no signal, check 3.3 V (pin63 RF) and X800.
2) Check TR- & TR+ from IC801 to PN800 for driving the tracking actuator.
If no signal, check +5 V for IC801.
3) Check if the FFC cable is solidly connected between PN800 and MD.
4) Check the MD.
If the pickup module has any trouble, it can not move the laser beam on the left or right side.
Please check the function after changing another MD.
4-4-3. Service hint (Any picture/ Remark)
TR-
TR-
pin15 to IC801
pin15 to IC801
TR+
TR+
pin16 to IC801
pin16 to IC801
< Waveform of TR±
for driving TRACKING actuator >
Summary of Contents for CM2460
Page 11: ...1 10 ...
Page 13: ...2 2 ...
Page 15: ......
Page 17: ...3 SPEAKER SECTION A60R A60L ...
Page 46: ...3 29 13 14 4 USB USB_5V D D Figure 4 14 13 ...
Page 47: ...3 30 ...
Page 54: ...3 58 3 57 SMPS P C BOARD BOTTOM VIEW ...
Page 55: ...3 60 3 59 2 MAIN P C BOARD TOP VIEW ...
Page 56: ...3 62 3 61 MAIN P C BOARD BOTTOM VIEW ...
Page 57: ...3 64 3 63 3 DISPLAY P C BOARD TOP VIEW ...
Page 58: ...3 66 3 65 DISPLAY P C BOARD BOTTOM VIEW ...
Page 59: ...3 68 3 67 4 KEY P C BOARD TOP VIEW BOTTOM VIEW ...
Page 60: ...3 70 3 69 ...