Installation
The wall you select should be strong and solid
enough to prevent vibration
1. Mount the installation plate on the wall with four
type A screws. If mounting the unit on a concrete
wall, use anchor bolts.
• Mount the installation plate horizontally by aligning
the centerline using a level.
2. Measure the wall and mark the centerline. It is
also important to use caution concerning the
location of the installation plate-routing of the
wiring to power outlets is through the walls typi-
cally. Drilling the hole through the wall for pip-
ing connections must be done safely.
• Drill the piping hole with a ø70mm hole core drill.
Drill the piping hole at either the right or the left
with the hole slightly slanted to the outdoor side.
• Open the Front Grille.
• Pass Telephone Control Cord Wire through the hole
which the power cord goes through.
• Connect Telephone Control Cord Wire to the phone jack
of telephone PCB of Control Box.
• Fix Telephone Control Cord Wire inside Control box so
as not to disconnect.
• Close the Front Grille.
How to Fix Installation Plate
Drill a Hole in the Wall
Drain hose junction
• Remove the rubber stopple in the desired drain direc-
tion.
• Insert drain hose into the handle of drain pan, and join
drain hose and connecting hose according to the figure
by.
5-7mm
(3/16"~5/16")
Indoor
WALL
Outdoor
Connecting
part
Adhesive
Drain
hose
Only the
desired direction
Type "A" screw
Installation Plate
Installation plate
Left rear piping
Right rear piping
C
D
B
A
Chassis
Hook
A
B
C
D
SD(24k)
120
110
43
43
CHASSIS
(Grade)
Distance (mm)
Summary of Contents for AS-H246DGM0