41
Disassembly
6. To remove the Fan motor
• Loosen the screw securing the cross-flow fan to
the fan motor (do not remove).
• Loosen the screw securing the mount motor.
• Separate the fan motor from the cross-flow fan.
• Take care not to drop the motor.
7. To remove the Cross-Flow Fan
• Loosen the screw securing the holder bearing.
• Lift up the cross-flow fan.
Screw
Fan motor
Screw
Screw
Fan motor
Mount motor
Holder bearing