GENERAL DATA
Table 1: Art Cool Premier Unit Specifications - Continued
Art Cool Premier Unit Specifications
Type
Art Cool Premier
Art Cool Premier
System (Model)
LA090HYV1
(LAN090HYV1/
LAU090HYV1)
LA120HYV1
(LAN120HYV1/
LAU120HYV1)
LA180HYV1
(LAN180HYV1/
LAU180HYV1)
LA240HYV1
(LAN240HYV1/
LAU240HYV1)
Fan
Indoor Type (Qty)
Cross Flow (1)
Outdoor Type (Qty)
Propeller (1)
Motor/Drive
Brushless Digitally Controlled/Direct
Airflow Rate
Indoor - Max/H/M/L (CFM)
547/494/417/283
742/565/424/318
777/565/424/318
Outdoor - Max (CFM)
1,165
2,119
Piping
Liquid Line (in, OD)
1/4
3/8
Vapor Line (in, OD)
3/8
5/8
Condensation Line (OD | ID)
27/32 | 5/8
Additional Refrigerant Charge (oz/ft)
0.22
0.38
Pipe Length (Minimum/Maximum) (ft)
5
6.6/65.6
9.8/98.4
Piping Length (no add’l refrigerant, ft)
5
41.0
24.6
Max Elevation Difference (ft)
32.8
65.6
EEV: Electronic Expansion Valve IDU: Indoor Unit ODU: Outdoor Unit
Power wiring is field supplied and must comply with the applicable local and national codes.
This unit comes with a dry helium charge.
This data is rated 0 ft above sea level, with 24.6 ft of refrigerant line per indoor unit and a 0 ft level
difference between outdoor and indoor units.
Cooling capacity rating obtained with air entering the indoor coil at 80ºF dry bulb (DB) and 67ºF wet
bulb (WB); and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).
Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 60ºF wet
bulb (WB); and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).
5
Piping lengths are equivalent.